{"product_id":"sf-box08220-bms-ip55","title":"SF-BOX08220-BMS-IP55","description":"\u003cul\u003e\n\u003cli\u003ePolyester quick-charging enclosure for streetlight\u003c\/li\u003e\n\u003cli\u003eDifferential, circuit breaker and SPD\u003c\/li\u003e\n\u003cli\u003eOutside dimensions 80x60x30cm\u003c\/li\u003e\n\u003cli\u003eSwitch 8 POE ports | Fiber Fusion Tray\u003c\/li\u003e\n\u003cli\u003eDegree of protection IP55 \/ DIN rail \u003c\/li\u003e\n\u003cli\u003eFast charge 17 amps\/hour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIntelligent cabinet for installations where there is no mains connection and light. Version 220V AC with fast charging 17 ampere hour connected to recommended Lithium battery (48V 100A) recommended for street lights, intelligent module integrated with main electrical protections (differential, circuit breaker and SDP), POE switch L2 with 2 HIGH POE sockets with SAFIRE logo. Additional application for carton weight.\u003c\/p\u003e\u003cul class=\"article_list\"\u003e\n\u003cli\u003eSafire\u003c\/li\u003e\n\u003cli\u003ePolyester cupboard\u003c\/li\u003e\n\u003cli\u003eAC input 220V cyclic load 17 ampere\/hours\u003c\/li\u003e\n\u003cli\u003eLithium battery 48V DC compatible\u003c\/li\u003e\n\u003cli\u003eIntegrated Smart Module\u003c\/li\u003e\n\u003cli\u003eOutput 12V 3A- Switch 8 POE ports (2x 90W, 6x 30W) L2\u003c\/li\u003e\n\u003cli\u003ex2 EU Plug\u003c\/li\u003e\n\u003cli\u003eAlarm input\u003c\/li\u003e\n\u003cli\u003eAdjustable DIN rail\u003c\/li\u003e\n\u003cli\u003eVentilation filter\u003c\/li\u003e\n\u003cli\u003eDoor tamper\u003c\/li\u003e\n\u003cli\u003eLighting for night maintenance\u003c\/li\u003e\n\u003cli\u003eWhite colour\u003c\/li\u003e\n\u003cli\u003eDimensions 800 x 600 x 300mm\u003c\/li\u003e\n\u003cli\u003eDegree of protection IP55\u003c\/li\u003e\n\u003cli\u003eDifferential, circuit breaker and SPD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"specs\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" style=\"\u0026gt;\u0026lt;tbody\u0026gt;\u0026lt;tr align=\" left valign=\"middle\"\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafire\u003c\/td\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyester cabinet with switch and power supply included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble key lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC input 100-240 V, DC 72 V, output 320 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePlug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ex2, European type F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRCD 1P+N, 16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTransient SPD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003exSPD 2P, AC380V, 20KA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMCB circuit breaker, 1P, DC220V, 16A, type C + 1P,DC220V, 16A, [%VAR%] type C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDC output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3x 12V DC, Max. 240W (between the 3 outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x 12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eLight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 12V\u003cbr\u003eInternal Led for night maintenance. Lights up when the door is opened\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDoor sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003exSwitch 8*10\/100\/1000M PoE (2*puertos 90W, 6*puertos 30W) + 2*1000 SFP, L2 administered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 inputs, dry contact\u003cbr\u003e*Input 1 used by default for the door contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eIntelligent network port module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100Base-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eReset button\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; Long press of 5 s: restore factory settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConverter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC converter 48 V to DC 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCharge controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum input voltage 100 V, battery support DC12 V\/24 V\/48 20 V, charging current [%VAR%] A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eLCD screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYesze: 2,5 inch LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber fusion tray\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x SC (connector) UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20℃~70℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStoring temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40℃~85℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0~90% no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 (H) x 600 (W) x 300 (D) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMC (fiberglass-reinforced polyester resin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eColour \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement software\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-header\"\u003e\u003ctd colspan=\"2\"\u003e\u003ch3\u003eSwitch\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-consumption \u0026lt; 20W, output \u0026lt; PoE180W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended POE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePorts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorts 1-2: 10\/100\/1000Base-T, 90 W, PoE RJ45 (IEEE 802.3bt, also compliant with IEEE8025.3af\/at); \u003cbr\u003ePorts 3-8: 10\/100\/1000Base-T, 30 W, PoE RJ45 (IEEE802.3af\/at) [%VAR%]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePorts 9~10, SFP slots 1000Base-X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.88Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMAC address table\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOvervoltage: 6 kV, standard: IEC61000-4-5\u003cbr\u003eESD: 6 kV: contacto\/8 kV: air, standard: IEC61000-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDate and time\u003cbr\u003eUser administration\u003cbr\u003eSecurity management (http, SNMP, telnet, SSH)\u003cbr\u003eConfiguration files (export\/import)\u003cbr\u003eFirmware\u003cbr\u003eSystem (restart, default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePort configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eState\u003cbr\u003ePort speed\u003cbr\u003eTraffic control\u003cbr\u003eStorm control (broadcast, interval, unicast, multicast)\u003cbr\u003ePort protection\u003cbr\u003eMAC Learning\u003cbr\u003eTrunk ports\u003cbr\u003eMirror Ports\u003cbr\u003eDHCP\u003cbr\u003eIGMP snooping\u003cbr\u003eVLAN\u003cbr\u003eLACP\u003cbr\u003eLLDP\u003cbr\u003eLoopback detection\u003cbr\u003eMAC VLAN\u003cbr\u003eVLAN mapping\u003cbr\u003eVoice VLAN\u003cbr\u003eMvr Interface\u003cbr\u003eOAM\u003cbr\u003eQinQ\u003cbr\u003eUdld\u003cbr\u003eJumbo frame\u003cbr\u003eDDM Information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMAC Link\u003cbr\u003eAuto link\u003cbr\u003eMAC filter\u003cbr\u003eBridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eVLAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWorking mode (access, trunk, hybrid)\u003cbr\u003eDefault VLAN\u003cbr\u003eMember tagued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSNMP configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSNMP community (community name, read, write)\u003cbr\u003eTRAP (SNMP version V1, V2C, V3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eACL configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard IP (Groups, source IP, wildcard, mathematical data packets)\u003cbr\u003eExtended IP (Groups, Source IP, Source wildcard, Destination IP, Destination wildcard, Protocol, Source port)\u003cbr\u003eIP MAC\u003cbr\u003eMAC ARP\u003cbr\u003eACL Reference\u003cbr\u003eTime range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eQoS configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQoS Application\u003cbr\u003eQoS Agenda\u003cbr\u003eIP Address\u003cbr\u003eARP\u003cbr\u003eHost static route\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAAA configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTacacs+\u003cbr\u003eRadius\u003cbr\u003eAuthentication 802.1X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSTP configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMSTP\u003cbr\u003eSTP port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eIGMP Snooping Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGMRP configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGMRP Global\u003cbr\u003eGMRP Ports\u003cbr\u003eGMRP Registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEAPS configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEAPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRMON configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatistics\u003cbr\u003eHistory\u003cbr\u003eAlarm\u003cbr\u003eEvents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCluster management\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNDP\u003cbr\u003eNTDP\u003cbr\u003eCluster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eLog information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLog\u003cbr\u003eSyslog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePOE power control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType\u003cbr\u003eAdmin status\u003cbr\u003eTotal energy\u003cbr\u003ePOE Policy\u003cbr\u003ePD Query\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDHCP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDHCP Snooping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eERPS configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eERPS\u003cbr\u003eERPS ring 1~21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eLACP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003elACP active links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eLine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eLLDP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGlobal\u003cbr\u003eHold multiplier\u003cbr\u003eTimer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDetection time\u003cbr\u003eProtocol\u003cbr\u003eResponse packages\u003cbr\u003eResponse time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMVR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroups\u003cbr\u003eVLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOAM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame with error\u003cbr\u003ePeriod\u003cbr\u003eSeconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForced\u003cbr\u003ePrimary port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eUDLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnable\u003cbr\u003eSchedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eVLAN protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eARP, Atalkaarp, Atalkddp, Atmmulti, Atmtransport, Dec, Deccustom, Decdiagnostics, Decnadumpload, Decdnaremoteconsole, Decnarouting, Declat, Desyscomn, G8bpqx25, IEEEaddrtrans, IEEEpup, IP, IPX, PPPdiscovery, PPPsession, Rarp, X25, Xeroxaddrtrans, Xeroxpup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC\u003cbr\u003eEnable\u003cbr\u003eLinktrace\u003cbr\u003eMA\u003cbr\u003eMD\u003cbr\u003eRule-mip\u003cbr\u003eService-instance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIn the box\u003c\/h3\u003e\u003cul class=\"article_list\"\u003e\n\u003cli\u003ePolyester cupboard\u003c\/li\u003e\n\u003cli\u003eInstallation material\u003c\/li\u003e\n\u003cli\u003eDin rail\u003c\/li\u003e\n\u003cli\u003eMast clamps\u003c\/li\u003e\n\u003cli\u003eBattery connection cable\u003c\/li\u003e\n\u003cli\u003ePlastic door key\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SAFIRE","offers":[{"title":"Default Title","offer_id":57325519962494,"sku":"SF-BOX08220-BMS-IP55","price":709.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0998\/5907\/1358\/files\/SF-BOX08220-BMS-IP55.png?v=1777328639","url":"https:\/\/giantwares.nl\/products\/sf-box08220-bms-ip55","provider":"Giantwares","version":"1.0","type":"link"}