{"product_id":"ebs2l-63a-2p","title":"EBS2L-63A-2P","description":"\u003cul\u003e\n\u003cli\u003eDifferential circuit breaker\u003c\/li\u003e\n\u003cli\u003eNominal current 63A\u003c\/li\u003e\n\u003cli\u003e2 poles (single-phase installations)\u003c\/li\u003e\n\u003cli\u003eSensitivity 30mA\u003c\/li\u003e\n\u003cli\u003eTrigger type A\u003c\/li\u003e\n\u003cli\u003eFor DIN rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EBS2L range of earth leakage circuit breakers are designed to quickly detect and cut off leakage current to earth, providing essential protection against electric shock and fire hazards in low voltage electrical installations. These devices comply with the IEC\/EN 61008-1, standard, which guarantees safe and reliable operation under international standards.\u003c\/p\u003e\u003cp\u003eAmong its advantages are versatility and compatibility: available in two current ratings and in 2 or 4 pole versions, making them useful in both single-phase and three-phase circuits. Simple installation on standard DIN rail with connections from above or below and good mechanical and thermal support for typical indoor environmental conditions.\u003c\/p\u003e\u003cp\u003eIn terms of usage scenarios, they are ideal for residential, commercial and small industrial installations where effective protection against earth leakage currents is required. The different sensitivities make them suitable both for protecting small circuits (kitchens or bathrooms) and for general distribution boards where overall system safety is required.\u003c\/p\u003e\u003cul class=\"article_list\"\u003e\n\u003cli\u003eDifferential circuit breaker\u003c\/li\u003e\n\u003cli\u003eNominal current 63A\u003c\/li\u003e\n\u003cli\u003e2 poles (single-phase installations)\u003c\/li\u003e\n\u003cli\u003eSensitivity 30mA\u003c\/li\u003e\n\u003cli\u003eTrigger type A\u003c\/li\u003e\n\u003cli\u003eFor residential, commercial and industrial installations\u003c\/li\u003e\n\u003cli\u003eDIN-rail installation\u003c\/li\u003e\n\u003cli\u003eIP20\u003c\/li\u003e\n\u003cli\u003e8000 mechanical life cycles\u003c\/li\u003e\n\u003cli\u003e4000 electrical life operations\u003c\/li\u003e\n\u003cli\u003eComplies with IEC\/EN standard 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"specs\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" style=\"\u0026gt;\u0026lt;tbody\u0026gt;\u0026lt;tr align=\" left valign=\"middle\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDifferential circuit breaker\u003c\/td\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail 35mm (EN 60175))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable \/ Pin-type busbar \/ U-type bus bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpper \/ lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eUpper connection section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35mm AWG 18\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eLower connection section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35mm AWG 18\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTorque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended conductor cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16mm2 (Nominal current of 50-63A))\u003cbr\u003e25mm2 (Nominal current of 63-80A))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.9 (W) x 81.7 (H) x 74.0 (D) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-header\"\u003e\u003ctd colspan=\"2\"\u003e\u003ch3\u003eELECTRICAL CHARACTERISTICS\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eType of leakage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromagnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRated input current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eType of shot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P (Single phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eRated jump capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit protection fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric test voltage at industrial frequency (1 min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum interruptible current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-header\"\u003e\u003ctd colspan=\"2\"\u003e\u003ch3\u003eMECHANICAL CHARACTERISTICS\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 - 40ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStoring temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 - 70ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIn the box\u003c\/h3\u003e\u003cul class=\"article_list\"\u003e\u003cli\u003eDifferential circuit breaker\u003c\/li\u003e\u003c\/ul\u003e","brand":"MARCA BLANCA","offers":[{"title":"Default Title","offer_id":57324686606718,"sku":"EBS2L-63A-2P","price":6.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0998\/5907\/1358\/files\/EBS2L-63A-2P.png?v=1777314511","url":"https:\/\/giantwares.nl\/products\/ebs2l-63a-2p","provider":"Giantwares","version":"1.0","type":"link"}