{"product_id":"asd533-2","title":"ASD533-2","description":"\u003cul\u003e\n\u003cli\u003eAspiration smoke detector\n\u003c\/li\u003e\n\u003cli\u003e2 sampling tubes (incl. SSD 533))\n\u003c\/li\u003e\n\u003cli\u003eDuct length 2x200 m\n\u003c\/li\u003e\n\u003cli\u003eMaximum area 3840 m2 \n\u003c\/li\u003e\n\u003cli\u003eQuiet operation (approx. 32 dBA)\n\u003c\/li\u003e\n\u003cli\u003eComplies with EN 54-20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSecuriton's ASD 533-2 is a highly sensitive aspirating smoke detector. It uses an active air sampling system through two pipes, continuously analyzing the presence of smoke particles by means of a large volume measuring chamber and a very sensitive HD sensor\u003c\/p\u003e\u003cul class=\"article_list\"\u003e\n\u003cli\u003eSECURITON\u003c\/li\u003e\n\u003cli\u003eAspiration smoke detector\u003c\/li\u003e\n\u003cli\u003e2 sampling tubes (incl. SSD 533))\u003c\/li\u003e\n\u003cli\u003eDuct length 2x200 m\u003c\/li\u003e\n\u003cli\u003eMaximum area 3840 m2 \u003c\/li\u003e\n\u003cli\u003eQuiet operation (approx. 32 dBA)\u003c\/li\u003e\n\u003cli\u003eComplies with EN 54-20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"specs\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" style=\"\u0026gt;\u0026lt;tbody\u0026gt;\u0026lt;tr align=\" left valign=\"middle\"\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e ASD 533-2 (aspiration detector for 2 pipelines)\u003c\/td\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \/ Certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 54‑20 classes A, B, C; UL and FM approvals (depending on version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of suction pipes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 independent sampling pipelines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. length. piping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to approx. 2 × 100 m (max. 200 m total, according to network design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity range (alarm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,02%\/m - 10%\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity range (pre-alarms)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,002%\/m - 9%\/m in steps of 10% of the threshold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 prealarms + 2 alarms (5 levels in total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,5 - 30 V CC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≈ 260 mA to 24 V CC (basic version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFan type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRadial, service life approx. 65.000 h at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuction noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≈ 32 typical dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface \/ Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm and fault relays, open collector, service interface\/USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 slots (p. e.g. SLM35, MCM35, RIM35)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66, ABS housing UL mixture 94‑V0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−30 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 397 × 265 × 146 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr align=\"left\" valign=\"middle\" class=\"table-data\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≈ 3,5 kg basic version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIn the box\u003c\/h3\u003e\u003cul class=\"article_list\"\u003e\u003cli\u003eAspiration smoke detector\u003c\/li\u003e\u003c\/ul\u003e","brand":"SECURITON","offers":[{"title":"Default Title","offer_id":57324537610622,"sku":"ASD533-2","price":1768.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0998\/5907\/1358\/files\/ASD533-2.png?v=1777313296","url":"https:\/\/giantwares.nl\/products\/asd533-2","provider":"Giantwares","version":"1.0","type":"link"}